| Specification |
|
Temperature [°C (°F)] |
Resistance (kΩ) |
|
-40 (-40) |
40.93 - 48.35 |
|
-20 (-4) |
13.89 - 16.03 |
|
0 (32) |
5.38 - 6.09 |
|
10 (50) |
3.48 - 3.90 |
|
20 (68) |
2.31 - 2.57 |
|
40 (104) |
1.08 - 1.21 |
|
60 (140) |
0.54 - 0.62 |
|
80 (176) |
0.29 - 0.34 |
Description Intake Air Temperature Sensor (IATS) is included inside Manifold Absolute Pressure Sensor and detects the intake air temperature.
Circuit Diagram Harness Connector
Instructions (R-134a) When Handling Refrigerant 1. R-134a liquid refrigerant is highly volatile. A drop on the skin of your hand could result in localized frostbite. When handling the refrigerant, be sure to wear gloves.
Description The ambient temperature sensor is located at the front of the condenser and detects ambient air temperature. It is a negative type thermistor; resistance will increase with lower temperature, and decrease with higher temperature.